<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>2012 Archives - Creative People | Quality IT services</title>
	<atom:link href="https://creativepeople.gr/tag/2012/feed/" rel="self" type="application/rss+xml" />
	<link>https://creativepeople.gr/tag/2012/</link>
	<description>Quality IT Services</description>
	<lastBuildDate>Mon, 11 Nov 2019 09:28:32 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://creativepeople.gr/wp-content/uploads/2020/02/fav.png</url>
	<title>2012 Archives - Creative People | Quality IT services</title>
	<link>https://creativepeople.gr/tag/2012/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Walkthrough Εγκατάστασης Intel Ethernet Card σε Server 2012 &#8211; 2012 R2</title>
		<link>https://creativepeople.gr/everyday-it-issues/walkthrough-%ce%b5%ce%b3%ce%ba%ce%b1%cf%84%ce%ac%cf%83%cf%84%ce%b1%cf%83%ce%b7%cf%82-intel-ethernet-card-%cf%83%ce%b5-server-2012-2012-r2/</link>
		
		<dc:creator><![CDATA[Chrysostomos Psaroudakis]]></dc:creator>
		<pubDate>Fri, 05 Feb 2016 18:37:16 +0000</pubDate>
				<category><![CDATA[Everyday IT issues]]></category>
		<category><![CDATA[Windows 2012R2]]></category>
		<category><![CDATA[2012]]></category>
		<category><![CDATA[intel]]></category>
		<category><![CDATA[windows server]]></category>
		<guid isPermaLink="false">https://cpltditdays.wordpress.com/?p=495</guid>

					<description><![CDATA[<p>Σε πολλές περιπτώσεις θα δείτε ότι είναι αδύνατη η εγκατάσταση Ethernet Καρτών κατασκευή της Intel ή Intel –Gigabit σε Η/Υ με λειτουργικό Windows Server 2012 /<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://creativepeople.gr/everyday-it-issues/walkthrough-%ce%b5%ce%b3%ce%ba%ce%b1%cf%84%ce%ac%cf%83%cf%84%ce%b1%cf%83%ce%b7%cf%82-intel-ethernet-card-%cf%83%ce%b5-server-2012-2012-r2/">Walkthrough Εγκατάστασης Intel Ethernet Card σε Server 2012 &#8211; 2012 R2</a> appeared first on <a href="https://creativepeople.gr">Creative People | Quality IT services</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Σε πολλές περιπτώσεις θα δείτε ότι είναι αδύνατη η εγκατάσταση Ethernet Καρτών κατασκευή της Intel ή Intel –Gigabit σε Η/Υ με λειτουργικό Windows Server 2012 / 2012 R2.</p>
<p>Η εγκατάσταση των driver σταματάει επειδή το software του driver δεν μπορεί να εντοπίσει Ethernet κάρτες της Intel.  Τo πρόβλημα υφίσταται διότι το πρόγραμμα εγκατάστασης της Intel προσπαθεί αυτόματα να εγκαταστήσει τον driver, ενώ θα έπρεπε να αφήσει το λειτουργικό σύστημα να αναλάβει την διαδικασία της εγκατάστασης. Επίσης έχει προστεθεί μια λίστα εξαιρουμένων συσκευών προς εγκατάσταση, που οδηγεί στο πάγωμα της εγκατάστασης των οδηγών.</p>
<p>Ο λόγος που γίνεται αυτό δεν είναι γνωστός και λογικά γίνεται στο να αποτρέψει χειριστές να εγκαθιστούν οδηγούς που ενδεχομένως να μην λειτουργούν σε ορισμένα setup.</p>
<p>Σφάλμα Εγκατάστασης Κάρτας Intel</p>
<p><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-499" src="https://creativepeople.gr/wp-content/uploads/2016/02/01.png" alt="01" width="339" height="161" srcset="https://creativepeople.gr/wp-content/uploads/2016/02/01-300x142.png 300w, https://creativepeople.gr/wp-content/uploads/2016/02/01.png 339w" sizes="(max-width:767px) 339px, 339px" /></p>
<p>Για να μπορέσει να πραγματοποιηθεί η εγκατάσταση χρειάζεται να προβούμε σε πολλαπλές ενέργειες  που θα εξαναγκάσουν την διαδικασία εγκατάστασης να ολοκληρωθεί.</p>
<p>Παρουσιάζουμε παρακάτω, αναλυτικά τα βήματα που πρέπει να ακολουθηθούν.</p>
<p><strong><u>Απενεργοποίηση</u><u> Driver Signing &amp; </u><u>Ενεργοποίηση</u><u> Test Mode</u></strong></p>
<p>Εκτελείτε το Command Prompt με δικαιώματα Διαχειριστή και δίνεται τις εξής εντολές.</p>
<p>bcdedit -set loadoptions DISABLE_INTEGRITY_CHECKS</p>
<p>bcdedit -set TESTSIGNING ON</p>
<p>Εφόσον εκτελεστούν οι εντολές κάνετε επανεκκίνηση τον Η/Υ.</p>
<p>Πλέον το λειτουργικό επιτρέπει την εγκατάσταση μη εγκεκριμένους οδηγούς συσκευών.</p>
<p><strong><u>Προετοιμασία </u><u>Custom</u> <u>Driver</u><u> προς εγκατάσταση. </u></strong></p>
<p>Αρχικά θα πρέπει να κάνετε download τον driver της συσκευής σας από το site του κατασκευαστή, εκτός και αν τον έχετε ήδη.</p>
<p>Στην συνέχεια κάνετε εξαγωγή τα αρχεία του driver κάπου στον Η/Υ. Στην περίπτωση του παραδείγματος ο οδηγός αφορά την κάρτα Intel 82579V Gigabit NIC και η εξαγωγή έγινε στο C:\temp\Intel_LAN_V17.1.50.0_Win8_Beta\PRO1000\Winx64\NDIS63.</p>
<p>Θα πρέπει να ανοιχθούν και να επεξεργαστούν όλα τα αρχεία .inf που περιέχουν τα hardware IDs της συσκευής.</p>
<p>Οπότε αρχικά θα πρέπει να βρούμε τα IDs της συσκευής, πηγαίνοντας στον Device Manager και επιλέγοντας την συσκευή που δυσλειτουργεί. Στο tab λεπτομέρειες  επιλέγουμε το Hardware IDS</p>
<p>Device Manager &#8211;&gt; Details&#8211;&gt;Hardware ID</p>
<p>Στην προκείμενη περίπτωση θα χρησιμοποιηθεί το ‘VEN_8086&amp;DEV_1503’. Στο δικό σας σύστημα πιθανότατα να είναι διαφορετικά τα IDs.</p>
<p><img decoding="async" class="alignnone size-full wp-image-498" src="https://creativepeople.gr/wp-content/uploads/2016/02/02.png" alt="02" width="404" height="204" srcset="https://creativepeople.gr/wp-content/uploads/2016/02/02-300x151.png 300w, https://creativepeople.gr/wp-content/uploads/2016/02/02.png 404w" sizes="(max-width:767px) 404px, 404px" /></p>
<p>Έχοντας πλέον και τον Vendor Και τα Hardware IDs μπορούμε να αναζητήσουμε στο φάκελο που εξάγαμε τον driver προηγουμένως , τα αρχεία που εμπεριέχουν τα συγκεκριμένα Hardware IDs.</p>
<p>Σε Powershell δώστε την ακόλουθη εντολή εφόσον έχετε πρώτα πλοηγηθεί στο φάκελο που έγινε η εξαγωγή του driver.</p>
<p>Get-Children –recurce | Select-String –pattern “το Hardware ID” | group path | select name</p>
<p><img decoding="async" class="alignnone size-full wp-image-501" src="https://creativepeople.gr/wp-content/uploads/2016/02/03.png" alt="03" width="585" height="120" srcset="https://creativepeople.gr/wp-content/uploads/2016/02/03-300x62.png 300w, https://creativepeople.gr/wp-content/uploads/2016/02/03.png 585w" sizes="(max-width:767px) 480px, 585px" /></p>
<p>Η εντολή αυτή θα μας επιστρέψει όλα τα .inf αρχεία σε όλο τον φάκελο και υπό φακέλους του οδηγού που αφορούν το συγκεκριμένο Hardware ID.</p>
<p>Εδώ μπορούμε να διαχωρίσουμε λίγο τα ζητούμενα αρχεία μιας και αν γνωρίζουμε την έκδοση του λειτουργικού μας, αν είναι 32bit ή 64bit.  Στην περίπτωση του παραδείγματος το λειτουργικό είναι 64bit οπότε θα επικεντρωθούμε στους φακέλους Winx64.</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-500" src="https://creativepeople.gr/wp-content/uploads/2016/02/04.png" alt="04" width="585" height="120" srcset="https://creativepeople.gr/wp-content/uploads/2016/02/04-300x62.png 300w, https://creativepeople.gr/wp-content/uploads/2016/02/04.png 585w" sizes="auto, (max-width:767px) 480px, 585px" /></p>
<p>Στον παρακάτω πίνακα αναγράφονται οι συσχετίσεις των εκδόσεων του οδηγού με τα λειτουργικά συστήματα.</p>
<table width="635">
<tbody>
<tr>
<td>Version</td>
<td>Desktop OS</td>
<td>Server OS</td>
</tr>
<tr>
<td>NDIS 6.0</td>
<td>Vista</td>
<td>*</td>
</tr>
<tr>
<td>NDIS 6.1</td>
<td>Vista SP 1</td>
<td>Server 2008</td>
</tr>
<tr>
<td>NDIS 6.2</td>
<td>Windows 7</td>
<td>Server 2008 R2</td>
</tr>
<tr>
<td>NDIS 6.3</td>
<td>Windows 8</td>
<td>Server 2012</td>
</tr>
<tr>
<td>NDIS 6.4</td>
<td>Windows 8.1</td>
<td>Server 2012 R2</td>
</tr>
</tbody>
</table>
<p>Βάσει των παραπάνω ο ζητούμενη έκδοση για το παράδειγμα μας είναι η NDIS63.</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-502" src="https://creativepeople.gr/wp-content/uploads/2016/02/05.png" alt="05" width="585" height="120" srcset="https://creativepeople.gr/wp-content/uploads/2016/02/05-300x62.png 300w, https://creativepeople.gr/wp-content/uploads/2016/02/05.png 585w" sizes="auto, (max-width:767px) 480px, 585px" /></p>
<p>Οπότε η αναζήτηση μας περιορίζεται μόνο σε ένα αρχείο, το e1c63x64.inf .</p>
<p>Στο παρακάτω πλαίσιο έχουμε αναγράψει της αλλαγές που πρέπει να γίνουν και αν ενσωματωθούν στο αρχείο e1c63x64.inf έτσι ώστε να ολοκληρωθεί η εγκατάσταση του οδηγού.</p>
<p>;**  Unless otherwise agreed by Intel in writing, you may not remove or      **</p>
<p>;**  alter this notice or any other notice embedded in Materials by Intel    **</p>
<p>;**  or Intel’s suppliers or licensors in any way.                           **</p>
<p>;******************************************************************************</p>
<p>;</p>
<p>;******************************************************************************</p>
<p>; e1c63x64.INF (Intel 64 bit extension Platform Only,</p>
<p>; Windows 8 64 bit extension)</p>
<p>;</p>
<p>; Intel(R) Gigabit Network connections</p>
<p>;******************************************************************************</p>
<p>;</p>
<p>[Version]</p>
<p>Signature   = &#8220;$Windows NT$&#8221;</p>
<p>Class       = Net</p>
<p>ClassGUID   = {4d36e972-e325-11ce-bfc1-08002be10318}</p>
<p>Provider    = %Intel%</p>
<p>CatalogFile = e1c63x64.cat</p>
<p>DriverVer   = 03/29/2012,12.1.10.0</p>
<p>[Manufacturer]</p>
<p>%Intel%     = Intel, NTamd64.6.2, NTamd64.6.2.1</p>
<p>[ControlFlags]</p>
<p>;ExcludeFromSelect = \</p>
<p>;    PCI\VEN_8086&amp;DEV_1502,\</p>
<p>;    PCI\VEN_8086&amp;DEV_1503</p>
<p>[Intel]</p>
<p>[Intel.NTamd64.6.2.1]</p>
<p>; DisplayName                   Section              DeviceID</p>
<p>; &#8212;&#8212;&#8212;&#8211;                   &#8212;&#8212;-              &#8212;&#8212;&#8211;</p>
<p>%E1502NC.DeviceDesc%            = E1502.6.2.1,       PCI\VEN_8086&amp;DEV_1502</p>
<p>%E1502NC.DeviceDesc%            = E1502.6.2.1,       PCI\VEN_8086&amp;DEV_1502&amp;SUBSYS_00011179</p>
<p>%E1502NC.DeviceDesc%            = E1502.6.2.1,       PCI\VEN_8086&amp;DEV_1502&amp;SUBSYS_00021179</p>
<p>%E1502NC.DeviceDesc%            = E1502.6.2.1,       PCI\VEN_8086&amp;DEV_1502&amp;SUBSYS_80001025</p>
<p>%E1503NC.DeviceDesc%            = E1503.6.2.1,       PCI\VEN_8086&amp;DEV_1503</p>
<p>%E1503NC.DeviceDesc%            = E1503.6.2.1,       PCI\VEN_8086&amp;DEV_1503&amp;SUBSYS_00011179</p>
<p>%E1503NC.DeviceDesc%            = E1503.6.2.1,       PCI\VEN_8086&amp;DEV_1503&amp;SUBSYS_00021179</p>
<p>%E1503NC.DeviceDesc%            = E1503.6.2.1,       PCI\VEN_8086&amp;DEV_1503&amp;SUBSYS_80001025</p>
<p>%E1503NC.DeviceDesc%            = E1503.6.2.1,       PCI\VEN_8086&amp;DEV_1503&amp;SUBSYS_04911025</p>
<p>&nbsp;</p>
<p>[Intel.NTamd64.6.2]</p>
<p>; DisplayName                   Section        DeviceID</p>
<p>; &#8212;&#8212;&#8212;&#8211;                   &#8212;&#8212;-        &#8212;&#8212;&#8211;</p>
<p>%E1502NC.DeviceDesc%            = E1502,       PCI\VEN_8086&amp;DEV_1502</p>
<p>%E1502NC.DeviceDesc%            = E1502,       PCI\VEN_8086&amp;DEV_1502&amp;SUBSYS_00011179</p>
<p>%E1502NC.DeviceDesc%            = E1502,       PCI\VEN_8086&amp;DEV_1502&amp;SUBSYS_00021179</p>
<p>%E1502NC.DeviceDesc%            = E1502,       PCI\VEN_8086&amp;DEV_1502&amp;SUBSYS_80001025</p>
<p>%E1503NC.DeviceDesc%            = E1503.6.2.1,       PCI\VEN_8086&amp;DEV_1503</p>
<p>%E1503NC.DeviceDesc%            = E1503.6.2.1,       PCI\VEN_8086&amp;DEV_1503&amp;SUBSYS_00011179</p>
<p>%E1503NC.DeviceDesc%            = E1503.6.2.1,       PCI\VEN_8086&amp;DEV_1503&amp;SUBSYS_00021179</p>
<p>%E1503NC.DeviceDesc%            = E1503.6.2.1,       PCI\VEN_8086&amp;DEV_1503&amp;SUBSYS_80001025</p>
<p>%E1503NC.DeviceDesc%            = E1503.6.2.1,       PCI\VEN_8086&amp;DEV_1503&amp;SUBSYS_04911025</p>
<p>;===============================================================================</p>
<p>;                WINDOWS 8 for 64-bit EXTENDED PLATFORMS</p>
<p>;</p>
<p>;===============================================================================</p>
<p>Ουσιαστικά διαγράφεται τις 3 γραμμές στο [ControlFlags] και στα version παρακάτω προσθέστε τα hardware IDs σας και αποθηκεύετε το αρχείο inf.</p>
<h3><u></u><u>Εγκατάσταση </u><u>Driver </u></h3>
<p>Στην συνέχεια εκτελείτε το setup του οδηγού, το οποίο θα ολοκληρωθεί αυτή την φορά.</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-503" src="https://creativepeople.gr/wp-content/uploads/2016/02/06.png" alt="06" width="632" height="461" srcset="https://creativepeople.gr/wp-content/uploads/2016/02/06-300x219.png 300w, https://creativepeople.gr/wp-content/uploads/2016/02/06.png 632w" sizes="auto, (max-width:767px) 480px, 632px" /></p>
<h3><u>Ενεργοποίηση </u><u>Driver</u> <u>Signing</u><u> &amp; Απενεργοποίηση </u><u>Test</u> <u>Mode</u></h3>
<p>Αφού ολοκληρωθεί η εγκατάσταση θα πρέπει να επαναφέρουμε τις ρυθμίσεις των Driver Signing &amp; test mode.</p>
<p>Εκτελείτε το Command Prompt με δικαιώματα Διαχειριστή και δίνεται τις εξής εντολές.</p>
<p>bcdedit -set loadoptions ENABLE_INTEGRITY_CHECKS</p>
<p>bcdedit -set TESTSIGNING OFF</p>
<p>Written and executed by <a href="https://www.linkedin.com/in/andreas-lavazos-69aa6652" target="_blank" rel="noopener noreferrer">Andreas Lavazos</a>@<a href="https://creativepeople.gr" target="_blank" rel="noopener noreferrer">CreativePeople</a></p>
<p><span id="dnn_ctr475_MainView_ViewEntry_lblCopyright" class="BlogCopyright">Copyright Creative People ©2016</span></p>
<p>&nbsp;</p>
<p>The post <a href="https://creativepeople.gr/everyday-it-issues/walkthrough-%ce%b5%ce%b3%ce%ba%ce%b1%cf%84%ce%ac%cf%83%cf%84%ce%b1%cf%83%ce%b7%cf%82-intel-ethernet-card-%cf%83%ce%b5-server-2012-2012-r2/">Walkthrough Εγκατάστασης Intel Ethernet Card σε Server 2012 &#8211; 2012 R2</a> appeared first on <a href="https://creativepeople.gr">Creative People | Quality IT services</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
